Every utility that takes leakage seriously ends up asking the same question: should we buy loggers, hire a logger survey, or just keep sending crews out with ground microphones? The sales pitch for each option is convincing on its own. Put them side by side and the right answer depends almost entirely on the network, not the equipment.
There are three ways to find non-visible leaks across a distribution network using acoustics:
All three use the same physics, covered in our guide to acoustic leak detection technologies. What differs is cost per kilometre, how long a leak runs before it is found, how well each method copes with your pipe materials, and how much of the work your own team has to do.
This guide sets out each method honestly, including where it falls down, then gives you a straightforward way to decide. It is written for the engineers and asset managers who have to put a number in next year’s budget, whether the network is 200 km or 5,000 km.
This is the method the industry was built on, and it is still how the majority of leaks in Australia and New Zealand are confirmed. A trained technician works systematically through the network, sounding every accessible fitting (valves, hydrants, meters, stop taps) with a listening stick, then using an electronic ground microphone along the line of the main where a noise is heard or where the pipe runs under unsealed ground. Suspects are pinpointed with a correlator before a mark goes on the road.
A good crew covers somewhere between 5 and 15 km of main per shift depending on fitting density, traffic and how much of the pipe is plastic. Most of the work happens at night, when the network is quiet and the roads are empty.
Where it is strong
Where it falls down
Ground survey is what most people mean when they say active leak detection, and for many regional councils it remains the most cost-effective option on its own. Our Torres Strait Island Regional Council programme, 94 leaks across 12 islands, was almost entirely ground survey: no logger network could justify itself on networks that small and that remote.
Lift-and-shift puts the overnight listening onto hardware. A crew deploys a batch of noise loggers (typically 30 to 100 units) across an area in the afternoon, magnetically attached to valves and hydrants at roughly 100 to 300 m spacing. The loggers record the quietest sound level and its consistency during the early hours, when customer use is lowest. The next day the crew drives past to download the data, lifts the loggers, and shifts them to the next area. Fittings flagged as suspect get a technician visit with a ground microphone and correlator.
Better loggers do more than measure loudness. Correlating loggers time-stamp their recordings precisely enough that neighbouring units can be correlated against each other in the office, giving a provisional leak position before anyone has been back to site.
Where it is strong
Where it falls down
Lift-and-shift is the backbone of most large water utility leak detection programmes we deliver, usually alongside targeted ground survey in plastic-heavy or high-density areas. The New Zealand councils programme shows what a sustained, repeated logger-led survey does to leakage over several years.
A permanent (fixed) network uses the same loggers, but they stay. Each unit is installed in a chamber with a cellular (NB-IoT or LTE-M) antenna and reports every night to a cloud platform. The software compares each fitting’s noise against its own history and its neighbours, and raises an alert when something new and persistent appears. Correlating units give a provisional position; a technician then confirms and pinpoints.
This is what the industry means by real-time leak detection, although “next-morning” is the more honest description.
Where it is strong
Where it falls down
Permanent networks make the most sense where the cost of leakage is high and the pipe material carries noise well: inner-city cast iron DMAs, networks with expensive bulk water or pumping, and critical zones where a burst has a large consequence. Our IoT devices page covers the hardware side.
Indicative figures for a mid-sized ANZ network with a mix of metallic, AC and plastic mains. Your numbers will move with fitting density, pipe material and local labour rates.
| Traditional ground survey | Lift-and-shift logger survey | Permanent logger network | |
|---|---|---|---|
| How leaks are found | Technician listens at every fitting and on the ground | Loggers listen overnight; technician follows up suspects | Loggers listen every night; alerts followed up as raised |
| Coverage per crew shift | 5–15 km | 30–50 km | n/a (continuous) |
| Time from leak starting to detection | Up to one survey cycle (12–18 months) | Up to one survey cycle (6–18 months) | Days |
| Cost model | Labour per km, no capital | Labour per km (lower), equipment owned by contractor or utility | Capital per logger + subscription + follow-up labour |
| Relative cost per km surveyed | Medium | Low | High up front, low per year once installed |
| Metallic and AC mains | Good | Very good | Very good |
| PVC and PE mains | Good (best option) | Poor to fair; tighter spacing needed | Poor to fair |
| Customer-side and service leaks | Good | Fair | Fair |
| Noisy urban areas | Difficult | Fair (loggers listen at quietest hour) | Good (trend data filters noise) |
| Repeatability between crews | Depends on technician | High at survey stage | High |
| In-house skill needed | High if self-delivered | Medium (follow-up and interpretation) | Medium plus alert management process |
| Ongoing maintenance | None | Minimal | Batteries, telecoms, software, chamber access |
| Best for | Small networks, plastic-heavy networks, remote areas, confirmation | Annual sweeps of large networks | High-value DMAs, critical zones, networks with expensive water |
The row that catches most people out is pipe material. A utility with 60% plastic mains that moves from ground survey to loggers on cost grounds often sees its find rate drop, then wonders why. The loggers are not faulty; the pipe is not carrying the noise to them.
Answer these four questions about your network and the right method usually falls out on its own.
1. What is the pipe made of? Pull the material split from the GIS. Above about 50% plastic, loggers need tight spacing or should give way to ground survey in those areas. Below that, loggers earn their keep.
2. What is leakage actually costing? Work out real losses in ML/year and multiply by the marginal cost of water (bulk purchase, treatment, pumping). Our ILI explainer and the economic level of leakage article will get you to a defensible figure, and the Water Loss ROI Calculator turns it into a business case. High cost of water favours permanent monitoring; low cost favours an annual sweep.
3. How long can a leak run before it matters? If a leak running six months is tolerable, a survey cycle is fine. If a burst in a particular zone would close a highway, flood a basement or drop supply to a hospital, that zone wants continuous monitoring regardless of what the rest of the network gets.
4. Who is going to do the follow-up? Every method ends with a skilled technician pinpointing a leak. If that capability is not in-house, the method needs to come with it.
Example A: regional council, 350 km, 55% AC, 30% PVC, 15% cast iron, cheap groundwater supply
An annual contracted survey is the answer. Lift-and-shift across the AC and cast iron areas, ground survey through the PVC estates, delivered in two or three weeks by a visiting crew. A permanent network cannot pay back against cheap water, and the council has nobody to manage alerts. This is the typical regional council profile and it is well served by a repeatable annual programme.
Example B: metropolitan utility, 4,000 km, mostly metallic and AC in the inner suburbs, PE in the growth areas, bulk water purchased at a high price
Lift-and-shift sweeps of the whole network every 12 months, plus permanent loggers in the 10 to 15 inner DMAs with the highest night flow and the most expensive consequence of failure. Ground survey is reserved for the PE growth areas and for follow-up. Night flow from the DMAs decides which areas get surveyed first and which get a permanent network.
Example C: mine site or remote camp, 40 km, mixed materials, water trucked or desalinated
Water is extremely expensive and the network is small. A permanent logger network across the whole site is often justified, with a ground survey at commissioning to clear the backlog and establish a quiet baseline. Follow-up is handled by the contractor on a call-out basis.
After enough survey cycles, almost every network settles on the same shape:
The equipment is the easy part. The programme is what reduces leakage, and it needs the three methods working together rather than competing for the same budget line.
Neither is more accurate; they do different jobs. Loggers are better at consistently screening a large metallic or AC network. A technician with a ground microphone is better on plastic pipe, service connections and in confirming the exact dig point. Every logger programme still ends with a technician.
Typically 100 to 300 m on metallic and AC mains, tighter on plastic, and generally one logger per fitting in dense older networks. Spacing is set by how far leak noise travels in that pipe, not by a fixed rule.
Yes, and some do it well. The common failure is buying the hardware without the follow-up capability, so suspects pile up unconfirmed. If the in-house team is small, a contracted survey that includes pinpointing usually finds more leaks per dollar.
Most ANZ utilities settle on every 12 to 18 months for the whole network, with high-loss DMAs surveyed more often or monitored permanently. The right interval is the one where the cost of another survey equals the value of the water it would save.
No. Night flow tells you how much water is being lost in an area; loggers tell you where. The two together are far more useful than either on its own.
Satellite and other remote-sensing methods can help prioritise which areas to survey first, but they do not locate leaks to a dig point. Every satellite-flagged area still needs one of the three acoustic methods above to find the leak.
Ground survey, lift-and-shift and permanent loggers are all proven. The mistake is treating the choice as a technology decision when it is really a question about pipe material, the value of water and how quickly a leak needs to be found. Answer those honestly and the method, or more likely the combination, is clear.
If you are planning next year’s leak detection budget, reviewing a logger proposal, or trying to understand why last year’s find rate was lower than expected, talk to our team. We deliver all three methods across Australia and New Zealand and will tell you which fits your network before we quote.
Read more about our active leak detection and acoustic leak detection services.
Satellites, smart meters and machine learning all have a place in a modern water loss programme. But when a utility actually needs to put a mark on the road and dig, the leak is almost always found the same way it was 40 years ago: by listening to it.
Acoustic leak detection remains the most reliable, lowest-cost way to locate non-visible leaks on pressurised water mains. The physics have not changed. What has changed is the equipment, the way it is deployed, and the number of brands competing for a place in a utility’s toolkit.
This guide walks through how acoustic leak detection works, the main technology categories, the brands you will see on tender submissions across Australia and New Zealand, and how to choose between them. It is written for the people who have to make those decisions: network engineers, asset managers, and the operations teams responsible for keeping water in the pipe.
If you are after the service rather than the theory, our acoustic leak detection for water networks page covers what we deliver and where.
Water escaping a pressurised pipe through a hole or crack creates turbulence. That turbulence generates vibration and sound, which travels in three ways: along the pipe wall, through the water column, and outward into the surrounding soil. Acoustic leak detection equipment picks up one or more of those signals and uses them to narrow a leak’s position from kilometres down to a hand-span.
Four variables decide how easy that is in practice:
Understanding those variables matters more than any single piece of equipment. Every technology below is a different trade-off between sensitivity, range, cost per kilometre and the skill required to interpret what it hears.
Most utilities end up using several of these in sequence: a wide-area tool to flag where leaks probably are, a correlator to narrow the search, and a ground microphone to confirm the dig point.
The listening stick is the oldest tool in the kit and still one of the most useful. A technician places it on a valve, hydrant or meter and listens directly for leak noise through the fitting. The electronic ground microphone does the same job on the surface above the pipe, with amplification and filtering that let the operator hear through road base and concrete.
These are confirmation tools. They do not find leaks on their own across a 300 km network, but no active leak detection programme marks a dig without one.
A correlator uses two or more sensors placed on fittings either side of a suspected leak. Each sensor hears the leak slightly out of time with the other. Knowing the distance between the sensors and the speed of sound in that pipe, the correlator calculates where the noise originates. On a metallic main in good conditions, that answer is accurate to within a metre or so.
Correlators are the workhorse for pinpointing on distribution mains and, with hydrophone sensors inserted into the water column, on large-diameter trunk mains. Our TM3 trunk main correlator case study shows the method finding something the client did not expect: an unauthorised connection rather than a leak.
Noise loggers are small sensors deployed on fittings across a DMA, usually one every 100–300 m. They record the quietest sound level at each fitting overnight. A steady, low, consistent noise floor points to a leak; a noise that comes and goes is more likely customer use. The loggers are either collected by a technician driving past (lift-and-shift) or left in place permanently, reporting over cellular networks.
Loggers are a survey tool. They tell you which fittings deserve a visit, which is how a crew can cover far more of a network per shift than by sounding every valve. Pairing them with district metered areas and night flow data is what turns a pile of noise readings into a prioritised work list.
A correlating logger does both of the above. Each unit time-stamps its recording precisely enough that a pair of neighbouring loggers can correlate against each other and give a leak position overnight, before a technician has even arrived. Deployed permanently, this is the basis of real-time leak detection on a fixed network, where new leaks are flagged within days of appearing rather than at the next annual survey.
For long trunk mains, outfalls and sewer rising mains, the most sensitive microphone is one travelling inside the pipe. Tethered tools are inserted through a single access point and pulled along by the flow, carrying a hydrophone (and often a camera) past every metre of pipe. Free-swimming tools go further still, released at one end and retrieved at the other, tracked from the surface as they go.
Because the sensor is in the water column, these tools hear leaks that are inaudible from the surface, including on plastic and large-diameter concrete mains where correlation struggles. The trade-off is logistics: insertion points, flow conditions and traffic management all need planning. Our inline pipeline inspection page and the top three trunk main leak detection methods article cover when each approach makes sense.
Some assets are too important to survey once a year. A permanently installed array of acoustic sensors along a critical trunk main, bridge crossing or pump station delivery main listens continuously and alerts the operator when a new noise signature appears. This is less about finding today’s leak and more about pipeline monitoring: catching the small leak before it becomes the burst that closes a highway.
No single manufacturer covers every category well. Our field teams carry equipment from several of the brands below, chosen for the job rather than the badge, and we are brand-agnostic when advising clients on what to buy. What follows is a plain description of where each brand sits, not an endorsement.
| Brand | Origin | Best known for | Where it fits |
|---|---|---|---|
| Gutermann | Switzerland | ZONESCAN fixed and lift-and-shift correlating loggers; AQUASCAN and MULTISCAN correlators; EASYSCAN ground microphone | Permanent DMA monitoring and real-time leak detection; strong on correlation between loggers |
| Sewerin | Germany | SeCorr correlators; AQUAPHON ground microphones and listening equipment | Pinpointing and confirmation; widely carried by Australian field crews |
| HWM (Halma) | UK | PermaNET+ and Permalog noise loggers; MicroCorr correlators; Xmic ground microphone | Large-scale logger deployments; long history on UK and Australian networks |
| Ovarro (formerly Primayer) | UK | Enigma correlating loggers; Phocus correlators; Eureka ground microphones | Lift-and-shift and permanent correlating logger programmes |
| Echologics (Mueller) | Canada | LeakFinderST and EchoShore correlation; ePulse acoustic condition assessment | Trunk main correlation using hydrophones; the same acoustic approach is used to estimate pipe wall condition |
| Xylem (Pure Technologies) | Canada / US | Sahara tethered inspection; SmartBall free-swimming inspection | In-pipe acoustic leak and gas pocket detection on large-diameter transmission mains |
| Acquaint | Netherlands | Acquarius and Aquabrella inline inspection tools | In-pipe inspection combining acoustics with condition data on pressure pipelines |
| Fuji Tecom | Japan | FSB-8 and related listening equipment; LC-series correlators | Robust, simple confirmation tools |
| SebaKMT (Megger) | Germany | Correlux correlators; Sebalog noise loggers | Pinpointing and logger surveys |
| vonRoll hydro | Switzerland | ORTOMAT permanent loggers and ORTOMAT-MTC correlating network | Permanent acoustic networks on distribution systems |
A few observations from the field on how these groups differ.
Logger-led brands (Gutermann, HWM, Ovarro, vonRoll) compete on battery life, radio range, the quality of their correlation between neighbouring units and, increasingly, the software that turns thousands of nightly readings into a short list. Hardware is converging; the software and the cost per logger per year are where the real differences now sit.
Pinpointing-led brands (Sewerin, Fuji Tecom, SebaKMT) are judged on how well a technician can hear through them in a noisy street at 2 am. Filtering, headphone quality and sensor sensitivity on plastic pipe matter more than the brochure.
In-pipe brands (Xylem, Acquaint, Echologics) are sold as a service as often as a product, because the deployment is the hard part. Aqua Analytics’ own AquaSnake tethered tool and AquaSphere free-swimming device sit in this category, developed because our clients needed live inspection of long trunk mains without a shutdown and without the mobilisation cost of importing a tool and crew for every job.
The wrong question is “which brand is best?”. The right one is “what is my network made of, how much is leakage costing me, and how often do I need to look?”. Five factors settle most decisions.
Most councils and utilities we work with land on a hybrid: a contracted annual or biannual acoustic survey across the distribution network, loggers left permanently in the two or three DMAs that misbehave most, and a trunk main programme on its own cycle.
Every brand on the list above will show you a demonstration leak found to the centimetre. What the demonstration cannot show is the plastic service line under a busy arterial road, the PRV chattering two blocks away, or the correlation that says 47 metres when the valve spacing on the plan is wrong by ten.
Acoustic leak detection is an interpretive skill. The equipment produces a signal; a person decides whether it is a leak, a customer running a tap, a pump, or nothing at all. That judgement is built over years of nights on the road, and it is the reason two crews with identical kit can return very different find rates from the same DMA.
At Aqua Analytics we call this the Human Layer. Our investment in technology is matched by our investment in the people who use it: structured training, mentoring from technicians with decades on the tools, and a career pathway that keeps experienced people in the field rather than losing them to the next job. If you would rather build that capability than buy it, we are always looking for people who want to learn the trade properly.
Acoustic leak detection is not one technology but a family of them, and the brands behind each are mature, competitive and broadly comparable on hardware. The decisions that actually move a utility’s leakage figure are about matching the tool to the pipe, setting a survey cycle the budget can sustain, and putting skilled people behind the equipment.
If you are scoping a leak detection programme, reviewing a logger tender, or trying to work out why last year’s survey found less than expected, talk to our team. We work across Australia and New Zealand and will give you a straight answer on what the network needs, whichever brand ends up on the truck.
Read more about our acoustic leak detection services for water networks.
Water loss percentages can be useful, but they rarely tell the full story.
For Australian utilities, the Infrastructure Leakage Index (ILI) provides a more accurate benchmark for real losses and helps determine whether leakage is within a reasonable range.
In this article, you will learn:
By the end, you will have a clearer view of how to interpret ILI and what to do with it.
The Infrastructure Leakage Index (ILI) is a benchmark used to measure how efficiently a water network is controlling real losses. It compares the amount of water currently being lost through leaks with the level of leakage that would still exist in a well-managed network of that size and type.
In simple terms, ILI helps answer this question: how much leakage is occurring beyond what is realistically unavoidable?
That makes it more useful than looking at water loss as a percentage alone. A percentage can be misleading because it does not account for factors like network length, number of connections, or operating pressure. Two utilities may report similar water loss percentages while performing very differently in practice.
ILI focuses specifically on physical leakage from pipes, fittings, service connections, and storage assets. It does not measure non-physical losses such as metering errors, billing issues, or unauthorised use.
For Australian utilities, ILI is a practical benchmarking tool. It helps teams understand whether leakage performance is broadly under control or whether closer investigation, targeted intervention, or better data is needed.
Water loss is often reported as a percentage, but that figure on its own can hide more than it reveals. A network losing 8% of supplied water may appear to be performing well, while another losing 12% may appear inefficient. In practice, those numbers do not account for differences in network size, connection density, operating pressure, or system layout.
That is the problem with percentage-based reporting. It treats very different networks as if they operate under the same conditions.
ILI gives utilities a more meaningful benchmark because it focuses on real losses in context. Instead of asking what share of water is being lost, it asks whether the level of leakage is high or low relative to what would be expected in that specific network.
For Australian utilities, that makes ILI far more useful for performance assessment. It supports better comparison across systems, helps avoid misleading conclusions, and gives decision-makers a clearer view of whether leakage is within a reasonable range or needs action.
ILI is calculated by dividing Current Annual Real Losses (CARL) by Unavoidable Annual Real Losses (UARL).
Put simply, it compares the leakage a utility is experiencing now with the lowest level of real loss that would still be expected in a well-managed system. If the result is close to 1, the network is operating near its unavoidable level of leakage. A higher result suggests there is more recoverable loss in the system.
The formula itself is straightforward. The harder part is producing reliable inputs. To calculate ILI properly, utilities need accurate data on real losses, network length, number of service connections, average pressure, and other core system characteristics. That is why strong water balance calculations are such an important starting point.
That is why data quality matters so much. If the underlying leakage, asset, or pressure data is incomplete or inaccurate, the final ILI figure can point teams in the wrong direction. Used with good data, ILI becomes a practical benchmark rather than just another reported number.
ILI is useful, but it only becomes meaningful when read in context. There is no single score that tells every Australian utility whether leakage performance is good or bad. A regional network, a dense metro system, and a mixed network with older assets may all produce very different results for valid reasons.
That is why ILI should be used as a benchmarking tool, not a standalone verdict. It is most useful when utilities compare performance over time, across pressure zones or DMAs, and against similar network types rather than treating one number as the full story.
For Australian utilities, the real value of ILI is in what it helps reveal. A rising ILI may point to growing leakage pressure, deteriorating assets, slower response times, or hidden losses that are not being picked up early. A stable or improving ILI can show that leakage programs, repairs, or pressure management strategies are working. The number matters, but the trend and the network conditions behind it matter more.
ILI is a useful benchmark, but it does not explain the cause of leakage on its own. It can show that real losses are higher than they should be, but it cannot tell you whether the issue is driven by pressure, hidden leaks, recurring bursts, ageing assets, repair quality, or incomplete data.
That is why ILI works best as part of a broader leakage performance framework. It gives utilities a strong starting point for understanding whether the network is underperforming, then other data points help explain why.
Used well, ILI can support benchmarking, trend analysis, and prioritisation. Used on its own, it can oversimplify the problem. A utility may know its ILI is high, but still need pressure data, minimum night flow trends, burst history, or zone-level monitoring to decide what action to take next.
In other words, ILI is a strong indicator, not a full diagnosis.
A high ILI usually points to leakage that sits above what should be expected in a well-managed network. Common reasons include:
A high ILI does not tell you which of these issues is driving the result, but it does show that closer investigation is needed.
If ILI is trending higher than expected, the next step is not to react blindly. It is to work through the likely causes and confirm where action will have the biggest impact.
Start with the basics:
ILI is most useful when it leads to focused action. The goal is not just to report leakage performance, but to identify what is driving it and where intervention will deliver the best return.
ILI is only as reliable as the data behind it. If a utility is working with incomplete flow records, inaccurate pressure data, outdated asset information, or gaps in consumption reporting, the benchmark can become less useful and harder to trust.
That matters because ILI is often used to support real decisions. Utilities may rely on it to assess performance, prioritise leakage programs, justify investment, or report to leadership. If the inputs are weak, the result may point teams in the wrong direction or hide the areas that need attention most.
Good benchmarking depends on having consistent, connected, and up-to-date network data. That includes not just system-wide figures, but the supporting detail needed to understand what is happening across zones, assets, and operating conditions. Better pressure flow and logging can play an important role here.
For Australian utilities, better data does more than improve reporting accuracy. It improves confidence. Teams can benchmark leakage performance more clearly, identify issues earlier, and make decisions based on evidence rather than assumptions.
Better leakage benchmarking does more than improve reporting. It helps utilities make clearer, more targeted decisions across operations, planning, and investment.
When ILI is backed by reliable network data, teams can see whether leakage is stable, improving, or drifting away from expected performance. That makes it easier to prioritise pressure management, leak detection, repairs, and renewals based on actual need rather than assumptions.
It also gives decision-makers a stronger basis for investment. Instead of relying on broad system averages, utilities can link leakage performance to specific zones, assets, or operating conditions. That leads to more focused programs and a better return on both operational and capital spend.
For Australian utilities, this is where benchmarking becomes genuinely valuable. The goal is not just to know the number. It is to use that insight to reduce avoidable loss, support long-term planning, and make smarter decisions across the network.
ILI is useful because it shows whether leakage performance is where it should be. What it does not do is tell utilities where losses are occurring, which assets or zones are contributing most, or what action should come first.
That is why benchmarking only becomes valuable when it is connected to broader network insight. When utilities combine leakage metrics with stronger visibility across pressure, flow, asset condition, and zone-level performance, they can move beyond broad reporting and start identifying the factors driving avoidable loss.
For Australian utilities, that means more than simply knowing performance is off track. It means having a clearer basis for prioritising investigations, targeting investment, and supporting better operational and planning decisions across the network.
Most utilities already have data. The challenge is turning that data into clear, practical direction.
A high ILI can show that leakage performance is off track, but it does not show where to focus first, what is driving the result, or how to respond in a way that delivers measurable improvement.
Aqua Analytics helps utilities close that gap. We support the full process, from water balance and NRW analysis through to DMA monitoring, pressure and flow insights, leak detection, and ongoing network visibility.
A key part of this is AquaNRW, our water loss software designed to help utilities, councils, and asset owners track ILI, minimum night flow, and leakage volume, while using DMA pressure data and a unified view of network inputs to highlight areas that need attention.
For utilities under pressure to reduce losses, justify spend, and make the most of limited resources, that matters.
Better visibility means faster decisions, stronger field prioritisation, and more confidence when planning operational or capital responses.
We help turn leakage metrics into action, so teams can focus effort where it will have the greatest impact.
If your utility needs a clearer view of leakage performance and the data behind it, contact us today to discuss how we can support smarter benchmarking and more targeted network action.
Trunk main leak detection is critical in managing large-diameter water pipelines. Due to their size and strategic importance, these pipelines require specialised techniques for effective leak detection.
Aqua Analytics offers three advanced solutions tailored for trunk main leak detection. Each uses innovative technology to ensure precision and efficiency.
This blog post will explore each of these solutions, highlighting their unique approaches and benefits.
The Trunk Main Correlator, utilising the advanced Gutermann TM2 technology, is designed for non-intrusive leak detection on large assets. This solution leverages surface-mounted sensors to detect leaks without requiring internal access to the pipeline.
The Gutermann TM2 employs highly sensitive surface-mounted sensors strategically placed along the trunk main. These sensors detect the acoustic signals generated by leaks, and the correlator processes this data to pinpoint the leak location with high accuracy. The device can be deployed with accelerometers or hydrophones.
The AquaSphere™ Free Swimming Leak Detection method involves an instrumented sphere inserted into a live trunk main without disrupting normal operations. This neutrally buoyant sphere travels with the water flow, continuously collecting data in real-time while being tracked above ground using IoT devices at pre-determined locations.
The instrumented AquaSphere is introduced into the pipeline through a specialised apparatus that handles high-pressure water network environments (or other suitable method that requires minimal civil work). As the AquaSphere moves with the water flow, the device collects acoustic data, which is saved onboard the device. Simultaneously, the device emits a signal, which is then received at tracking points along the length of the pipeline to assist with localisation and the pinpointing of leaks. This method can cover over 100km in a single deployment, making it ideal for remote trunk mains in rural environments. For more information, download the AquaSphere Fact Sheet.
The AquaSnake Tethered Leak Detection system utilises a sensitive hydrophone attached to a cable and parachute to navigate the live pipeline without any interruption to customers. This method provides live 1080p HD CCTV and acoustic data, with an operator monitoring progress at the insertion location and another above-ground tracking the device in real time for instant marking of leaks or anomalies.
The device is inserted into the live pipeline, with the parachute aiding its movement through the water flow. Operators stationed in a truck control the cable deployment and monitor the live CCTV and acoustic feed, while a second operator tracks the device’s progress above ground using a sonde. The device has up to 1km of cable and can go around bends. For more information, download the AquaSnake Fact Sheet.
Aqua Analytics stands out in water loss management and our approach to trunk main leak detection due to our comprehensive range of trunk main technologies and expert local teams. Our solutions are designed for quick mobilisation and cost-effective deployment, ensuring that large-diameter leak detection is efficient and accurate.
Here’s why Aqua Analytics is the preferred choice:
Trunk main leak detection is essential for maintaining the integrity and efficiency of large-diameter water pipelines. Aqua Analytics’ advanced solutions, including the Trunk Main Correlator, Free Swimming Leak Detection Device, and Tethered Leak Detection, provide accurate, efficient, and cost-effective leak detection services.
Our range of leak detection technologies and trained local teams ensure we can quickly and effectively address any leak detection needs, safeguarding your water infrastructure and ensuring reliable service.
Contact Aqua Analytics today for more information on our trunk main leak detection services or to schedule a consultation. With our cutting-edge technology and expert solutions, we can help you protect your valuable water assets.